Fluid Mechanics Laboratory
Flow Visualization Apparatus
Country of Origin | Made in India |
Usage | Flow Visualization Apparatus |
Design | As per picture |
Size | N/A |
Condition | New |
Colour | Blue |
Additional Information:
- Item Code: FM15
Cavitations Test Rig
Type | Cavitations Test Rig |
Usage/Application | Laboratory Equipment |
Brand | EEE |
Country of Origin | Made in India |
Condition | New |
Design | as per picture |
Additional Information:
- Item Code: FM18
Laminar Flow Apparatus
Country of Origin | Made in India |
Condition | New |
Colour | Blue |
Brand | EEE |
Design | as shown in picture |
Weight | N/A |
Additional Information:
- Item Code: FM16
Pressure Measurement Apparatus
Color | Pepsi Blue |
Brand | EEE |
Additional Information:
- Item Code: FM21
Darcys Law
Brand | EEE |
In 1856, a hydraulic engineer named Henri Darcy, from the city of Dijon, France developed the first documented apparatus for observing the movement of water through a porous medium. He found that the water flow through his apparatus was proportional to the difference in the height of the water between the two ends of the apparatus, which, in turn, is inversely proportional to the length of the flow path. Also, Darcy discovered that the quantity of flow depends on the nature of the porous medium. However, before Darcy made these discoveries, there were two other scientists, Gotthilf Hagen (1839) and Jean Louis Poiseulle (1846), who discovered that the rate of flow of water through capillary tubes is proportional to the hydraulic gradient. From his experiment, Darcy was able to derive a formula through which the rate of flow could be calculated. This became known as Darcy's Law: Q=KiA
Range of Experiments :
1. The results of Darcy's experiments indicated that the rate at which a fluid moves through a porous
medium (Q) is proportional to the difference in hydraulic head of the water along the column and the characteristics of the porous medium and the column length.
Hydrology Apparatus ( Rainfall Hydrograph)
Brand | EEE |
Material | Sump Tank - SS |
Range of Experiments :
1. Hydrographs from single or multiple storms2. Effect of a moving storm on flood hydrograph3. Effect of reservoir storage on flood4. Effect of land drains on flood hydrograph5. Storm hydrograph from a previously saturated catchment hydrograph6. Storm runoff from an impermeable catchment
Additional Information:
- Item Code: FM-35
Losses in Pipes Apparatus
EEE” Losses in Pipes Apparatus is a self contained, compact set up which helps in studying the losses due to sudden enlargement, contraction, bends, elbows in pipelines.It consists of a supply tank with necessary piping. Supply from the pump is taken by flexible piping and water is delivered to the set up through a control valve and a Rotameter. Rotameter is mounted on a frame for flow measurement. After measuring the water discharge at specific time intervals, water in main tank can be released into drain tank by opening the valve provided.
Range of Experiments:
1.To determine loss of head due to sudden contraction.2.To determine loss of head due to enlargement.3.To determine loss of head in an elbow.4.To determine loss of head in a band.
Additional Information:
- Item Code: FM-08
Center of Pressure Apparatus
Minimum Order Quantity: 1 Unit
Brand | EEE |
Color | Blue |
Additional Information:
- Item Code: FM20
- Delivery Time: 6-8 weeks
Electrical Analogy Apparatus
Minimum Order Quantity: 1 Unit
Introduction :
Electrical Analogy Apparatus helps students to study the similarity between flow of electric current and flow of water through a closed conduit. The flow in the first system is governed by the Ohm's law whereas that in the latter case is governed by DarcyWeisbach equation. The apparatus consists of a transparent tray 450 mm x 400 mm x 100 mm deep in which hydraulic models under study such as Orifices, Mouthpieces,weir etc., Can be arranged.
The necessary conductor and insulator plates (Bakelite) will be cut by the user as per the
requirement. A trolley mounted on the tray can be traversed in two planes on which probe can be
mounted and equipotential lines traced.Trolley will be fitted with scales to locate probe positions.
Additional Information:
- Item Code: FM19
- Delivery Time: 5 weeks
Heleshaw Apparatus
Minimum Order Quantity: 1 Unit
Introduction :
“EEE” Heleshaw Apparatus is made out of Perspex sheets. Water and dye are allowed to flow from the two small tanks, one containing water and other containing a dye solution , placed at the top of Perspex sheets. Small holes are drilled at the bottom of these two tanks; which open between the spacing between two Perspex sheets. At the bottom a small tube with pinch cock is provided which controls the flow. It is possible to keep a transparent sheet of paper against one of the Perspex sheets and trace out the streamline pattern. By changing the model, change in the streamline pattern can be studied.
Additional Information:
- Item Code: FM13
- Production Capacity: as per order
- Delivery Time: 4-5 weeks
Flow Measurement By Venturi Meter & Orifice Meter Apparatus
Country of Origin | Made in India |
Usage | Laboratory |
Design | as per picture |
Colour | Blue |
Condition | New |
Brand | EEE |
“EEE” Venturimeter & Orificemeter apparatus is useful for calibration of Venturimeter and orificemeter.
Range of Experments :
1. Construction difference in venturimeter and Orificemeter .2. Flow Measurement by Venturimeters.3. Flow Measurement by Orificemeters.
Additional Information:
- Item Code: FM-02A
Reynold''S Apparatus
Condition | New |
Model Number | FM-01 |
Sump Tank | SS |
Sump Tank (Millimeter) | (600 X 400 X 200) mm |
Color | Blue |
Brand | EEE |
Application | To determine the Reynolds number & hence the type of flow either laminar or turbulent |
Material | SS / MS |
Range of Experiments:
- To determine the Reynolds number &hence the type of flow either laminar or turbulent
- To determine upper &lower critical Reynolds numbers and velocities
Additional Information:
- Item Code: FM-01
Bernoulli''S Theorem Apparatus
Material | Sump Tank -SS |
Introduction :
“EEE” Bernoulli's Theorem Apparatus is a self contained, compact set up which helps in verifying Bernoulli's Theorem for liquids. It consists of a supply and delivery tanks between which water is allowed to flow through a horizontal Perspex channel, of varying cross sections. Pressure heads can be noted from piezometer tubes fixed on the channel. Supply from the pump is taken by flexible piping and drain could be given to the diversion arrangement for discharge measurement. Overflow and drain arrangement is provided for the supply and delivery tank. A scale for height measurement and stop clock is supplied with the apparatus.
Range of Experiments :
- Verification of Bernoulli's Theorem for liquids
Additional Information:
- Item Code: FM-03
Flow Measurement By Venturi Meter & Orifice Meter
Minimum Order Quantity: 1 Unit
Brand | EEE |
Color | Blue |
Range Of Experiments:
- Calibration of venturimeters
- Calibration of orificemeters
Additional Information:
- Item Code: FM-02
- Delivery Time: 6-8 weeks
Notch Apparatus
Brand | EEE |
Material | SS / MS / Acrylic |
Range of Experiments:
- To determine coefficient of discharge through.
- “V” Notch.
- Rectangular Notch
- Trapezoidal Notch
Additional Information:
- Item Code: FM-05
Pipe Friction Apparatus
“EEE” Pipe Friction Apparatus is a self contained, compact set up which helps in studying thecoefficient of friction in various types of notches.It consists of a supply tank with necessary piping. Supply from the pump is taken by flexible piping and water is delivered to the set up through a control valve and a Rotameter. Rotameter is mounted on a frame for flow measurement. After measuring the water discharge at specific time intervals, water in main tank can be released into drain tank by opening the valve provided.Water is allowed to flow through pipes of varying diameters and of different materials, alternately and head loss due to friction is measured by using manometer.
Range of Experiments :
Determination of coefficient of friction of GI pipe :½” Cu pipe :½” Al pipe :½” MS Pipe : ½” To plot relation between pressure loss &flow rates for a particular pipe diameter.
Additional Information:
- Item Code: FM06
Losses in Pipes Apparatus
Minimum Order Quantity: 1 Unit
Additional Information:
- Item Code: FM08
- Delivery Time: 6-8 weeks
Free & Forced Vortex Flow Apparatus
Minimum Order Quantity: 1 Unit
Brand | EEE |
Material | Acrylic / SS / MS |
Color | Blue |
- To visualised the forced and Free vortex phenomenon
- To plot the shape of vortex profile i.e. vertical height Vs. Horizontal Radius
Additional Information:
- Item Code: FM-12
- Delivery Time: 6-8 weeks
Orifice Meter Apparatus
Minimum Order Quantity: 1 Unit
Brand | EEE |
Color | Blue |
Additional Information:
- Item Code: FM10
- Delivery Time: 6-8 weeks
Orifice & Mouthpiece Apparatus
Minimum Order Quantity: 1 Unit
Brand | EEE |
Material | Stainless Steel |
Color | Blue |
Range of Experiments:
- Coefficient of discharge, Cd
- Coefficient of velocity, Cv
- Coefficient of contraction, Cc of given orifice and mouthpiece
Additional Information:
- Item Code: FM-04
- Delivery Time: 6-8 weeks
Pitot Static Tube
Usage/Application | Laboratory |
Shape | As per picture |
Weight | N/A |
Brand | EEE |
Country of Origin | Made in India |
Colour | Blue |
Additional Information:
- Item Code: FM11
Impact of Jet Apparatus
Brand | EEE |
Introduction :
“EEE” Impact of Jet Apparatus is a self contained, compact set up which measures the force exerted on the plates by the water jet, Allows the student to study the theoretical momentum, laws verify impact of jet practically.
Range of Experiments :
1. To determine coefficient of impact for the vanes lever.
2. To calculate theoratical and pracitcal forces for different types of blades.
Additional Information:
- Item Code: FM07
Laminar Flow Table
Brand | EEE |
1. Ideal flow around immersed bodies
- cylinder
- aerofoil
- bluff body.
2. Ideal flow in channels and at boundaries convergent channel divergent channel 90 degree bend sudden contraction sudden
enlargement replacement of a streamline by a solid boundary.
3. Ideal flow associated with sinks and sources
- formation of a Rankine half body
- formation of a Rankine oval circular
- streamlines from a doublet
- superposition of sinks and sources.
4. Use of streamlines to analyse two-dimensional flow.
Additional Information:
- Item Code: FM-16B
Measurement of Surface Tension
Minimum Order Quantity: 1 Number
Brand | EEE |
Model | FM-42 |
Application | Laboratory, Industrial, Engineering colleges |
1. Determine the surface tension of olive oil as a function of temperature.
2. Determine the surface tension of water/methanol mixtures as functions of the mixture ratio.
Additional Information:
- Item Code: FM-42
Venturimeter Apparatus
Brand | EEE |
Material | Acrylic |
Color | Blue |
Additional Information:
- Item Code: FM09
- Delivery Time: 6-8 weeks
Laminar Flow & Turbulent Flow Apparatus
Range of Experiments :
1. Laminar /Turbulant flow study with respect Reynold number
2. Head loss comparison in Laminar /Turbulent flow
Additional Information:
- Item Code: FM-16A
Metacentric Height of Ship Model
Minimum Order Quantity: 1 Unit
Range of Experiments :
1. Determination of metacentric Height of a war ship.
2. Determination of metacentric Height of a cargo ship.
Introduction :
“EEE” Metacentric Height of Ship is a compact apparatus and requires minimal installation . The ship model is floated on water, and is tilted by moving a small weight at the level of the deck of
the ship. To note down the tilt of the ship a plumb is provided which records the tilt on a graduated arc of a circle. An arrangement is made to load the war ship or cargo ship.
Additional Information:
- Item Code: FM14
- Delivery Time: 5 weeks